Antenna input to connect the 'hot' pole of the antenna to terminal 1
2
and the shield to terminal 2
OPEN Input. It activates feature to operate just with loop detactor or
3
timer (as long as the contact remain closes, the barrier stays open.
5
When contact reopens, the barrier closes after the time set on TCA).
START input. It opens the barrier when it is closed, it stops the barrier
4
while opening (if DIP2 = OFF), it closes the barrier when it is open, and
5
reopen during closing.
5
STOP Input. If activated it stops every movement.
6
PHOTO input with DIP3 = OFF barrier reverses movement during
7
closing and during opening it is ignored. With DIP3 = ON after
9
photocells are disengaged, barrier closes after 3 sec. without
considering time set on TCA.
8
SAFETY EDGE Input (COSTA). It works only during opening; it stops the
barrier and closes for 1 sec.
9
9
Input for closing limit switch. N.C. contact
10
9
Input for opening limit switch. N.C. contact
11
Output for photocells. Powered only during movement of the barrier.
12
Useful for energy saving while barrier is still and mandatory in order
13
to use feature PHOTOTEST DIP6=ON. (max 150mA)
GREEN = 0V
1 2 3 4 5 6
BROWN = +5V
ENCODER
J1
SW1
WHITE = SIGNAL
LED1
INS
LED2
DEL/PED
F1
6 • PROGRAMMING
It must be carried out after installing all safety devices, in order to reduce risk of injury.

Preliminary checks:

• Connect control panel to the electricity mains.
• Check that all LEDs are switched off (except DL10). If photocells are powered through output 12-13 LED DL7, must be switched on.
• Select throughout Dip4 the type of feature you are using (PUNTO6 or PUNTO4 have both electric limit switches and encoder); so set dip4 in OFF (standard)
barrier works both with limit switches and encoder, set dip4 in ON it works ONLY with limit switches (old Punto 24).
STANDARD programming with barrier using both limit switches and encoder (dip4 OFF); suitable for Punto 4 - Punto 6.
SET PLASTIC CAMS IN THE WAY THEY TRIGGER THE SWITCHES BEFORE THE LEVER HITS THE MECHNICAL STOPPERS, BOTH IN OPENING AND CLOSING.
IMPORTANT: close the barrier (boom horizontal position and limit switches on closing engaged), led DL10 must be ON.
1. Hold button PRGM down until led DL2 begins flashing and then remains steady.
2. Give a 1° START command (or remote control command previously stored as in the instructions), the barrier opens.
3. While opening is almost completed, give a 2° START command, to set slowing down position in opening. The barrier will continue the travel until the opening
mechanical stopper is hit and the led DL2 turns off. After 3 seconds the barrier closes automatically.
4. While closing is almost completed, give a 3° START command to set slowing down position in closing. The barrier will continue the travel until the closing
mechanical stopper sis hit.
5. Programming is over now.
IMPORTANT: slowing down position both in opening and closing is set when you press the START button and NOT when limit switches are triggered.
If within 10 seconds from point 2 the sequence of programming has not started, led DL2 turns off and the procedure is terminated automatically.
During programming procedure any STOP command or photocell intervention will cause the termination of programming procedure (The barrier stops, the led DL2
turns off and program is cancelled). It is mandatory to follow strictly the sequence described above.
CL
OP
TCA
PWR
PWR
RX433
DL1
DL2
DL3
- +
- +
- +
DL4
START PRGM
DL6
DL7
DL8
DL10
DL11
T1
T2
J2
M
24 Vac
Permanent output power to photocells. Attention! Use only with
13
feature PHOTOTEST disabled DIP6 = OFF otherwise the barrier
14
won't work and the blinker lights up steadily. 14+/13- (max 150mA)
15
Output for additional accessories 24Vdc 13-/15+ (max. 500mA)
13
15
Flashing light output: intermittent output 24Vd DC max 10W
16
SPIA Output DIP5 = OFF, fast flashing light during closing, slow flashing
15
during opening, continuous light when barrier is open, flasher switched
17
off when barrier is closed
15
Traffic light output DIP5 = ON light on when barrier is completely
17
open (24 Vac Max 10W)
18
Backup battery input 18-/19+ (with no. 2 batteries 12V-2,2AH
barrier opens at least 100 times)
19
T1
Motor output 24 Vdc.
T2
J1
ENCODER connector
J2
Connector for secondary input of the transformer 24 Vac
1
ANT
2
3
PED
4
START
COM
5
STOP
6
FOTO
7
8
COSTA
9
COM
10
FCC
11
FCA
+ 24 Vdc FOTOTEST
12
- 24 Vdc
13
14
+ 24 Vdc
15
LAMP
16
17
SPIA
- BATT
18
19
+ BATT
1 2 3
1 2 3 4 5 6