- ページ 9
スキャナー DURKOPP ADLER 550-867のPDF 補足説明をオンラインで閲覧またはダウンロードできます。DURKOPP ADLER 550-867 20 ページ。 Btsr sensor
Replacing the thread tension PCB
Putting on the antistatic armband
1. Fasten the antistatic armband (2) to the mechanic's arm.
2. Fasten the clamp (3) of the antistatic armband (2) to equipotential
Abb. 6: Antistatic armband
Removing the PCB
1. Loosen all four screws (7) and remove the PCB (5).
2. Release the screws (6) on the plugs.
3. Pull off the plug (6).
Abb. 7: Removing the PCB
Additional Instructions 550-867 - 01.0 - 08/2017
bonding (4) on the control cabinet.
②
②
(2) - Antistatic armband
(3) - Clamp
⑤
⑥
(5) - PCB
(6) - Plug
④
(4) - Equipotential bonding
⑦
(7) - Screws
③
④
③
⑥
7