- ページ 20
液晶テレビ Acer AT4250B seriesのPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Acer AT4250B series 39 ページ。 Acer lcd tv user's guide
Acer AT4250B series にも: クイック・スタート・マニュアル (2 ページ), (フランス語) 利用ガイド (20 ページ)
Altitude
Units tested at an altitude up to 12,000 feet must operate at normal conditions without exhibiting abnormal
behavior such as arcing or shutdown.
Operating altitude: 0 to 12,000 feet
Shipping altitude:
Storage altitude:
Vibration Test
The packaged display shall be capable of passing sinusoidal vibration test as specified in follows.
A. Test condition as below :
B. The unit under test shall be run for a duration of 30 minute in each of following orientations :
a. Top and bottom side ( z axis ).
b. Left and right side ( x axis ).
c.
The unit shall suffer no visible cosmetic damage and should operate no degradation indisplay quality after test.
Additionally, prior to production and prior to implementation of any design or manufacturing change that might affect
vibration performance, a minimum of 2 units shall be demonstrated to meet the requirements of specification.
14
0 to 40,000 feet
0 to 40,000 feet
1) Random vibration,10-500 Hz, 1.47G RMS
Front and rear side ( y axis ).
Chapter1