- ページ 12
アクセサリー Elsat iNode:0x0809のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Elsat iNode:0x0809 15 ページ。 Care sensor pht
iNode Care Sensor PHT – instruction manual
4.
Technical information
Bluetooth Low Energy:
configurable from your PC:
◦ the power with which the device operates in the range of-18 dBm + 8 dBm (maximum range up to 200 m
in open space);
◦ the name of the device;
◦ the threshold pressure value resulting in sending an alert;
◦ the threshold temperature value resulting in sending an alert;
◦ the threshold humidity value resulting in sending an alert;
◦ type of archived information;
◦ group (logical network) to which alerts are sent;
◦ the password of the user;
◦ the password to access the device; independent of the user's password, the password for the authorization
application on the smartphone or PC (protects against its copying and use by another client);
Power supply:
the battery CR2032;
Housing:
plastic;
dimensions: Ø 32 mm x 9.5 mm;
Other:
remote firmware update;
two LEDs;
operating temperature: from -30 to 65 °C;
humidity: 10-90 % RHG;
weight: 5 g;
Additional pressure sensor LPS331AP:
Operating pressure range :
260 to 1260 hPa
Relative accuracy over pressure:
±0.1 hPa/±0.2 hPa (typ./max.) P = 800 to 1100 hPa, T= 25°C
Absolute accuracy pressure:
3.2 hPa/±2 hPa/+2.6 hPa (min./typ./max.) P = 800 to 1100 hPa, T= 0 to +80°C
Measurement Resolution:
±0.0625 hPa
Additional temperature sensor Si7021:
Accuracy:
±0.3°C/±0.4°C (typ./max.) -10°C to +85°C
Measurement Resolution:
±0.01 °C
Additional humidity sensor Si 7021:
Accuracy:
±2%RH/±3%RH (typ./max.) 0% to 80%
±2%RH/±4.5%RH (typ./max.) 80% to 100%
Measurement Resolution:
±0.025%RH
Equipment:
the battery CR2032;
Software:
Windows XP/Vista/7.0/8.0/8.1/10.0;
Linux;
ELSAT s.c.
page 12