- ページ 10
ゲートオープナー Elsema iS300のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Elsema iS300 12 ページ。 Swing gate opener
1.3 TECHNICAL FEATURES:
A. Technical Features:
Motor Voltage
Gear Type
Max Absorbed Power
Peak Thrust
Nominal Thrust
Stroke Length (CD)
Power Supply
Nominal Input Current
Maximum Operating Current
Maximum Gate Weight
Maximum Gate Length
Duty Cycle
Operating Temperature
Dimension
Weight
B Dimension:
1.4 MAINTENANCE
Maintenance should be performed at least every six months. If it is used in high traffic area, a
more regular maintenance should be performed.
Disconnect the power supply
(1)
Clean and lubricate the screws, the pins and the hinge with grease.
(2)
Check the fastening points are properly tightened.
(3)
Check and make sure that the wire connections are in good condition.
Connect the power supply
(1)
Check the power adjustments.
(2)
Check the function of the manual release
(3)
Check the photocells or other safety device.
8
:
:
:
iS300/iS300D/iS300Solar SWING GATE OPENER MANUAL
24Volts DC motor
Worm gear
144 Watts
3000N
3000N
350mm
240 Volts AC
2 Amps
5.5 Amps for maximum 10 sec
300 kg per leaf
3 metres
20%
-20°c ~ +50°c
812mm x 123mm x 124mm
6.6 kg