- ページ 3

掃除機 Dust Care 4000 Quiet SeriesのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Dust Care 4000 Quiet Series 11 ページ。 Central vacuum systems

Appliance installation
• Avoid placing objects on your machine. Make sure that nothing blocks
or penetrates the ventilation openings of the motor.
• The machine should be installed in an area where the temperature does not
exceed 40° C.
Appliance maintenance
• Cleaning of the canister should generally be done every three or four months.
• The filter can be washed with soapy water.
Troubleshooting
If suction decreases:
• Clean the filter by hand-shaking it. Certain dust particles may block the
filter more easily than others (ex. Gyproc dust).
• Empty the canister.
• Check all the rubber gaskets inside the covers of the wall outlets.
• If the two motors stop, re-start them by pressing the reset button.
Caution
• Never use vacuum without filter.
• Never use vacuum to suck water.
• It is recommended to check the carbon brushes after five years of use
(domestic use).
4
PLANNING

Tools Required

Steel Tape Measure • Phillips Screw Driver • Wire Cutters • Keyhole Saw
Hammer • Chisel • Wire Coat Hanger • 2 1/2" Hole Saw • 1/2" Electric Drill
If you don't have a 1/2" drill and intend to rent one from a tool rental store ask for a
"Right-Angle drill". This type of tool will save drilling time and allow you to work in very
tight spaces.
Planning
Each inlet kit contains a sufficient number of fittings to complete most installations.
Some installations, however, may require additional fittings. As our installation shows,
there are instances where either a 45° Ell or a sweep 90° could be used. Remember,
it requires two 45° Ells to form a 90° elbow.
Maximize your fittings, because, should you need another 90° Ell to complete the instal-
lation, you might only have one 45° Ell left, leaving the installation incomplete.
Study the instructions thoroughly and study the illustrations of the various options avail-
able for the installation of your system.
After you have planned your system, count all components in your kit to ensure
that you will have sufficient parts and fittings for the completion of the installation.
Inlet valves may be installed in more than one location to service the area you wish to
cover from any one inlet valve. Study the diagrams and choose the method that best
suits your requirements.
Power Unit Location
In selecting the power unit location the following points should be carefully considered.
Install the power unit as far away from the living area as possible so that normal
activities can be carried out with as little noise as possible coming from the power unit
while vacuum cleaning is in progress. This also insures that there is no recirculation of
dust in the living area.
An ideal location for the power unit would be the garage where the unit's inlet valve
will come in handy when you wish to vacuum your car and changing the filter will be
easier. Other suitable locations can also be found in a basement, basement crawl space,
furnace room, under weather-proof sun deck, laundry room, carport or any ventilated
storage area.
Typical two story residence showing proposed location for power unit.
5