- ページ 7
照明器具 Dust Free 19300のPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。Dust Free 19300 13 ページ。 Germicidal uv-c ultraviolet light
Dust Free 19300 にも: インストレーション&オペレーションマニュアル (5 ページ)
DUST FREE
LIGHTSTICK
®
DIRECT LAMP INSTALLATION
• Drill a 7/8" knockout in the outer sheet
metal where the lamp will be centered on
the return side of the coil. See diagram.
• Place gasket (included) around knockout.
• Insert lamp into power module and
secure with self-drilling screws.
(Included.)
• Insert lamp/power module assembly
directly into knockout and secure with
self-drilling screws (Included.) Note:
A-Coil delta plate installation does not
use lamp bracket.
POWER MODULE
INSTALLATION
• Drill a 7/8" knockout in the outer sheet
metal where the power cord will be
inserted.
• Connect the power module to constant
24VAC power.
• Connect lamp connector to power
module connector. Connectors are
keyed for proper alignment.
WARNING
Electric Shock Hazard.
Can cause injury or death.
Disconnect all electrical power supplies
before servicing.
WARNING
For Use With 24VAC Only.
Do not exceed voltage rating.
Severe damage to device and/or fire could
result. Verify proper voltage.
INSTALLATION & OPERATION MANUAL
®
(Direct Lamp)
(A-Coil Delta Plate)
Fig. 6 Insert lamp into power module
and secure with screws.
Fig. 7 Insert assembly into delta plate
knockout and secure with screws.
7