- ページ 6
照明器具 Dust Free BIO-FIGHTER 4XtremeのPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。Dust Free BIO-FIGHTER 4Xtreme 9 ページ。 21", 33", 45" ultraviolet light systems
BIO-FIGHTER® 4XTREME INSTALLATION & OPERATION MANUAL
STRAIGHT-LAMP INSTALLATION
To maximize the efficiency and life of the UV-C
lamp, clean each lamp prior to installation.
Use isopropyl alcohol and cotton cloth to wipe
dust and fingerprints from the lamp.
To install the lamp in its straight-lamp con-
figuration the lower slide bracket must be
removed. After the lower slide bracket has
been removed gently insert lamp into lamp hole
and push upper slide bracket over the retaining
lip of the lamp and tighten the two knurled nuts
until the lamp is securely fastened.
Remove lower slide bracket.
Lamp retaining lip
Fig. 7 After lower slide clip is removed, slip upper slide bracket
over retaining lip of lamp and tighten two knurled nuts.
WARNING
Electrical disconnect required.
Areas where UV fixtures are installed must
have access panel/door disconnect
switches installed. Never view UV-C light
without protective eyewear.
CONNECTING THE HARNESS
(Fig.7 )
After lamp has been installed, attach electrical
harness. The harness connector is asymmetri-
cal and can only be attached one way. If the
harness does not attach easily, rotate 90
degrees and try again.
Fig. 8 Attach electrical harness to lamp.
FINISH INSTALLATION
Upper slide bracket
Close the cover, reinstall the cover retaining
screws, and turn on the electrical service.
Apply included warning label on nearby main-
tenance access panel.
Note: This device uses a cover safety inter-
lock. The cover must be closed for the device
to operate.
OPERATION
The device operates continuously. It is recom-
mended that the device be interlocked with a
power disconnect to prevent inadvertent UV-C
exposure when access panels are removed.
6
(Fig.8 )