ETH1 CONNECTOR
ETH1 is a 4-pin Female D-Coded M12 connector. It is used to connect the QLM500 to an
EtherNet/IP network in either Daisy-Chain, Ring or Star topologies.
ETH2 CONNECTOR
ETH2 is a 4-pin Female D-Coded M12 connector. It is used to connect the QLM500 to an
EtherNet/IP network in either Daisy-Chain, Ring or Star topologies.

AUX CONNECTOR

AUX is a 5-pin Female B-Coded M12 connector. It is used to connect the reading device
connected to the QLM500 to a configuration program on a PC. For example for the
DS2100N/2400N/4800 barcode readers you should use the Genius™ configuration tool.
You can use the CAB-AUX 03 accessory cable to easily connect the QLM500 to a PC DB9
serial port.
SYSTEM WIRING/CABLING
The connection and wiring procedure for QLM500 is described as follows:
1) Be sure that all the QLM500 M12 connectors are free (not connected).
2) Build your power supply cable using the CBL-1487 accessory connector following the
pinout shown in the Connectors paragraph (PWR-IN Connector). Use an adequate
cable/wire diameter, according to the total current required for the application (QLM500,
connected reader, trigger, other I/O devices, ID-NET™ Network components). One of the
CS-A2-02-G-xx accessory cables can also be used (see PWR-IN paragraph).
3) Connect the power supply cable to the QLM500 (with no other devices connected) and
apply power checking that the polarity is correct: the blue LEDs below both PWR-IN and
ID-NET (out) M12 connectors must be turned on. If instead the red LEDs are turned on,
the polarity is incorrect; switch off the power and check the cable. Correct the situation so
that the power supply polarity is correct.
4) When the connection to the power supply is correct switch off the power.
5) Connect the reading device to the 25-pin connector.
6) If your application requires it, connect a PNP photocell to the TRG connector. Several
commercial cables are available (see TRG Connector paragraph).
7) If your application involves other I/O devices you can build your I/O cable using the
FMC600 accessory and following the pinout shown in the Connectors paragraph (I/O
Connector); next connect your cable to the I/O connector.
8) If an ID-NET™ network is required in your application, build the network using the proper
Datalogic Automation accessory cables, connectors and termination cap. See the Typical
Layouts for example.
9) Connect the QLM500 to the EtherNet/IP Network using proper Ethernet cables. If the
ETH2 connector is not used to propagate the network, use the M12 protection cap.
QLM500 INSTALLATION MANUAL