インターホン・システム 2easy DMR12/ID/D8のPDF クイック・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。2easy DMR12/ID/D8 2 ページ。 Dt 2-wire system dmr12 door station

2easy DMR12/ID/D8 クイック・インストール・マニュアル
1. Introductions
Door Station is a unit installed on the entrance of a building, which used to call a
user in a apartment, and control the electronic lock opening.
This is a guide for quick installation. for more detail instructions, please refer to the
DT system technical guide.
To call the user, press a button with a associated nameplate of the user; then the
user will press the Unlock button on the monitor to open the door for the visitor if
she/he is accepted.
A ID card can be use to open the door.(Only for DMR12/ID series Door Station).
For detail ID card operation, please refer to DT system technical guide.
A exit button can be connect to the Door Station directly.
The Camera angle can be adjusted to coordinate the install position of the Door
Station

2. Parts and functions

Speaker
Camera Lens
Microphone
Camera Angle
adjustment
Name plate
Call button
With rainy cover
-1-
3. Terminals
12VDC power output.
+12V:
power ground.
LK-(GND):
electronical load activation ralay contact common.
LK+(COM):
electronical load activation ralay normally open contact(refer to DT technical
NO.:
guide for Lock connection detail informations).
Exit button.
EB+:
Exit buton.
EB-:
For electronic lock safety type setting(refer to Door Station Lock
JP-LK:
Connections).
USB-RS485 communication terminal negative.
T/R-:
USB-RS485 communication terninal positive.
T/R+:
DIP switches for system configurations.
SET:
L1,L2
non-polarised bus line.
Bus(
):
4. Connections
This example is one door station wiring, note that the lock used here is a 12Vdc 300mA
power-to-unlock type. (please refer to DT technical guide for Lock connection detail
informations)
3
2
1
Electronic Lock
+12V
L1
-
LK - (GND)
BUS
LK+(COM)
+
N.O.
EB -
EB+
Exit Button
Connect to DPS or DBC4S
-2-

5. DIP Switches settings

Total 6 bits in the DIP switches can be configured. The switches can be modified
either before or after installation.
RS-485
3
2
1
+12V
L1
L2
LK - (GND)
LK+(COM)
N.O.
EB -
EB+
• Bit-1 and Bit 2 is for door station ID settings, when mutil door stations are
BUS
installed in the system, these two bit must be set correctly, the first door
station set to 00, the second one set to 01, the third one set to 10, the fourth
one set to 11. If only one door station is installed, set to 00.
• Bit-3: Single line button door station or double line button door station
selection. If the door station is a double line button, for examlpe, the DMR12/
D16, set this bit to 0, set to 1 for single line button door stations.
• Bit-4: Button code selection; if use the default codes for each button of the
door station, set to 0, if use the programmed codes, set to 1.(the code for
each button can be program by the 2Easy+TOOL software, see the program
section in this manual)
• Bit-5: Unlocking time quick selection, by default it is set to 0, for 1 second
unlocking time; set to 1 for 5 seconds(by default).
• Bit-6: Set to 1,it is for door station ID settings,for examlpe,the DMR12/ID/
S4 and DMR12/ID/D8 must be set to 1;set to 0,it is not for door station ID
settings,for example,the DMR12/S8 and DMR12/D16 must be set to 0.

6. Place Name Plate

L2
1.Remove the bottom cover
ON(1)
OFF(0)
ON
ON
2.Remove the anti-theft screw
3.Extract name plate folder,
replace name plate.
-3-