- ページ 11
アクセサリー Datalogic Smart-VS WebAppのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Datalogic Smart-VS WebApp 16 ページ。 Smart vision sensor
SETTINGS
This page contains Job Settings and Global Settings.
It can be reached using the hamburger icon on the upper right corner.
The parameters under Job Settings are variable for each job, which means that any
change will only be valid for the current job:
•
•
The parameters under Global Settings are common to all jobs, which means that any
change will be valid for all jobs:
•
•
•
•
•
•
•
Trigger Input Delay: the delay to apply prior to the acquisition process of the trig-
ger event. It is measured in time (ms). This parameter can be adjusted along with
image acquisition: images are shown on the related window.
Trigger Input Debounce: filter debounce time measured in μs.
Trigger Input Event: can be either Leading or Trailing.
Output Hold Time: the time (ms) during which the output data remains valid.
Output Mode: available selections are NPN, PNP, Push-Pull active High, Push-Pull
active Low.
Remote Teach Input Event: available selections are Leading and Trailing.
Remote Teach Input Debounce: filter debounce time measured in μs.
Aiming System: available selections are Always ON, Always OFF, Calibration Only.
Green/Red Spots: available selections are Calibration Only, Enabled, Disabled.
SETTINGS
7
USER'S GUIDE