- ページ 2
アクセサリー Datalogic SRX3のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Datalogic SRX3 5 ページ。 High performance ultrasonic fork sensors for transparent label detection
TECHNICAL DATA
SPECIFICATION
Minimum pulse time
Detectable size
Max. tape speed
Tape size
Ultrasonic frequency
ELECTRICAL DATA
Power supply
Current consumption
Ripple
Output current
Output saturation voltage
Rising time
Falling time
Power On delay
Response time
Switching frequency
Output
MECHANICAL DATA
Connection
Operating temperature
Storage temperature
Humidity
Vibration
Shock resistance
Housing material
Protection class
Weight
DIMENSIONS
M12 CONNECTOR
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
2
4
1
3
1 - TEACH-IN PUSH BUTTON
2 - MODE LED
3 - STATUS LED
4 – SENSING POINT REFERENCE
1ms
> 2mm
60m/min
> 16mm
300 Khz
12...30 Vdc
< 55mA
10%
250 mA max.
< 1,5V @ 100mA
0,8 us max
1,6 us max
325 ms
1ms
500 hz
PNP / NPN
M12 5 pin
0 °C ... +50 °C
-25 °C ... +75 °C
35...85% rH non condensing
Aluminium
IP54
300g
M8 CONNECTOR
1
CATALOG | Photoelectric Sensors
2
4
3
151