- ページ 2
アクセサリー Datalogic TL46-WLFのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Datalogic TL46-WLF 2 ページ。 Contrast sensor
Select "dLOF" from the parameter menu to set DELAY OFF function.
The parameter programming is accessed by pressing
.
The previously set delay value appears on the display.
Pressing
or
the delay value is increased or decreased by one step of
1 ms until a maximum delay of 100ms. Keeping press
or
value is increased or decreased by incremental step. The setting of a delay
different from zero is signalled by the DELAY LED on. Press
the value and return to the parameter menu.
PNP/NPN output setting
The digital output can be configured as PNP or NPN.
Select '_PnP' or '_nPn' in the parameter menu to switch the output.
The previously set output switches by pressing
.
UP/DOWN DISPLAY setting
The selection of the UP/DOWN display sets the reading direction on the
display.
Select "dSUP" or "dSdn" in the parameter menu to set the UP or DOWN
direction.
Press
to switch the reading direction previously set.
ON/OFF DISPLAY setting
Turn off the display during normally working to save power consumption.
Setting the OFF mode, when the sensor is functioning normally, the display is
OFF. It turns on for 5s after a keyboard command. Select "dSOn" or "dSOF"
in the parameter menu to set the display ON or OFF.
Press
to switch the display mode previously set.
RESET of default parameters
Select "rSEt" in the parameter menu to reset the default parameters.
The "rSEt" text blinks when pressing
.
Releasing the push-button the sensor returns to normal functioning.
The default reset parameters are:
PARAMETER
DISPLAY
DESCRIPTION
________
Emission
Green
________
DARK/LIGHT mode
Light
Threshold
2050
Hysteresis
Medium (Normal)
Delay ON and OFF
Deactivated
Digital output
PNP output
Display
Display UP ON
NOTE: if the parameters are reset before turning the sensor off, when
repowered the "rSEt" text blinks on the display for 3s before returning
to normal visualisation.
Saving parameter set - "SAVE"
Select "SAVE" to save the parameter setting
The parameters are saved pressing
and releasing it the display returns to
normal visualisation.
NOTE: Set the data, the operator exits from the menu using the "SAVE"
or "RESET" function. If these operations are not carried-out 30s after
the last setting, the sensor returns to normal mode saving the
parameters changed.
ACCESSORY FUNCTIONS
REMOTE INPUT
The REMOTE signals carries-out the acquisition functions without using the
push-button.
The REMOTE wire connected to +Vdc is equal to pressing the
button. Whereas, if the REMOTE wire is connected to GND or not connected
the delay
it is equal to not pressing the
push-button.
to confirm
REMOTE
PUSH-BUTTON
0V
NOT PRESSED
+Vdc
PRESSED
- The duration of the REMOTE wire connection to +Vdc determines the
acquisition type:
V
cc
STATIC
>1s
REMOTE
DET.
GND
Mark detection
V
cc
DYNAMIC
4s
REMOTE
DET.
GND
Dynamic detection
(begin) start
DARK/LIGHT input
The DARK/LIGHT signal allows the operator to select the DARK/LIGHT
operating mode for dynamic detection.
In the LIGHT mode the output is active with light marks on dark backgrounds,
in the DARK mode the output is active with dark marks on light backgrounds.
The connection of the DARK/LIGHT wire to Vdc sets the DARK mode.
If connected to 0V or not connected set the LIGHT mode.
DARK/LIGHT
MODE
0V
LIGHT
+Vdc
DARK
EX-II-3DG IP67 T6
T6 (<85°C)
Temperature class:
Max. Power consumption 1000 mW at 30 Vdc
Max. Internal capacitance 100 nF
Internal inductance:
negligible
DECLARATION OF CONFORMITY
We DATALOGIC AUTOMATION declare under our sole responsibility that these products are conform
to the 2004/108/CE and successive amendments.
WARRANTY
DATALOGIC AUTOMATION warrants its products to be free from defects.
DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be defective
during the warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of DATALOGIC
AUTOMATION products.
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A. and the E.U.
826003103 Rev.C
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
push-
Background detection
Dynamic detection
end
© Copyright Datalogic 2007-2012