WARNING: Too much air pressure causes a hazardous risk of bursting. Check the
manufacturer's maximum pressure rating for air tools and accessories. The regulated outlet
pressure must never exceed the maximum pressure rating.
4.
Place the pressure switch ON/OFF lever in the ON position. The motor will stop when air tank
pressure reaches "cut-out pressure".
5.
An air pressure regulator is in use, open the regulator by turning it clockwise. Adjust the
regulator to the correct pressure setting. Your unit is ready for use.
When You Are Finished:
6.
Turn the air compressor unit off.
7.
Turn the regulator counterclockwise and set the outlet pressure to zero.
8.
Remove the air tool or accessory.
9.
Open the regulator and allow the air to slowly bleed from the air tank. Close the regulator when
air tank pressure is approximately 20 PSI.
10. Open the drain valve underneath the air tank and drain water from air tank.
WARNING: DRAIN AIR TANK DAILY. Water will condense in the air tank. If not drained, the
water will corrode and weaken the air tank, causing a risk of air tank rupture. The air tank must
be drained properly.
11. After the water has been drained, close the drain valve.
if the air compressor is under continuous use, drain at least once each day.
-
if the air compressor is only used occasionally, drain after each use.
-
MAINTENANCE
WARNING: Unit cycles automatically when power is on. During maintenance, you could be
exposed to voltage sources, compressed air, moving parts, or hot surfaces. Personal injuries
can occur. Unplug the unit and bleed off all air tank pressure and allow unit to cool before
doing any maintenance or repair. Never operate the unit with the belt guard removed.
To ensure efficient operation and longer life of the air compressor unit, a routine maintenance
schedule should be prepared and followed. The following routine maintenance schedule is geared to
a unit in a normal working environment operating on a daily basis. If necessary, the schedule should
be modified to suit the conditions under which your air compressor is used. The modifications will
depend upon the hours of operation and the working environment. Air compressor units in an
extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.
Routine Maintenance Schedule
Daily:
1.
Check oil level. Add if necessary.
WARNING: Overfilling with oil will cause premature air compressor pump failure. Do not
overfill.
2.
Open the regulator and allow the air to slowly bleed from the air tank. Close the regulator when
air tank pressure is approximately 20 PSI.
3.
Drain water from the air tank, any moisture separators, or transformers.
4.
Check for any unusual noise and/or vibration.
5.
Manually check all safety valves to make sure they are operating properly.
6.
Inspect for oil leaks. Take unit to an Authorized Service Center for repair.
7.
Inspect air filter and replace if necessary.