4. Press the Latch to open the Peel and Present Assembly. Then remove the C-Clip that secures the
Upper Roller Shaft to the Front Cover.
Latch
5. Remove the Upper Roller Shaft and the associated Rollers.
6. Using a Cotton Swab dampened with alcohol, wipe all Roller and Upper Roller Shaft surfaces
clean. Pay special attention to the ridges on the Rollers to ensure that they are clean.
Note: For cleaning heavy deposits from the Rollers and Shafts in the following steps, WD-40
or another non-damaging adhesive remover can be substituted for isopropyl alcohol –
provided this adhesive remover is carefully applied using a cotton swab.
7. Slide the Rollers back onto the Upper Roller Shaft, place the components into the Front Cover,
and reinstall the C-Clip.
C-Clip
Front Cover
Upper Roller
Shaft
7
Upper Roller
Shaft
Rollers