- ページ 8

産業機器 DUUN EP75 EI-PTOのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。DUUN EP75 EI-PTO 11 ページ。

Preparations for use

Attachment to the firewood processor

The EP75 and EP110 have wheels and can be easily moved by driving them like a wheelbarrow.
They are attached to the firewood processor using drawbar bolts illustrated with A.

Power connection

The electrical operation requires three phases and a fuse according to the counter size and volt.
EP75
7.5 kw motor that gives 400 rpm on the firewood processor tap.
Fits VM320 and VM370
16A fuse at 400 volts
32A fuse at 230 volts
EP110
11kw motor that gives 400 rpm on the firewood processor tap.
Fits VM320, VM370 and 370x
32A fuse at 400 volts
63A fuse at 230 volts
Important at start-up to see if the motor turns in the correct direction!
The motor is marked with a sticker (A) which shows the direction of rotation of the motor's fan.
If the fan rotates in the opposite direction than indicated on the sticker, contact an electrician and turn
on the power to correct the direction.
8