Maintenance
To adjust the packing:
1. Ensure the spray gun is depressurized.
2. Unscrew the trigger housing from the main
body by turning counter-clockwise and
completely removing it, along with the fluid
needle and trigger piston (See Figure 10).
!
CAUTION:
The needle spring is under
pressure and is retained by this cap. It may
spring free when the cap is removed.
3.
Insert a thin, flat-blade screwdriver into the
rear of the main spray gun body (See Figure
11) and turn the fluid seal nut 1/4 turn
clockwise to tighten or counter-clockwise to
loosen (See Figure 12 & 13).
4. Reinstall the trigger housing with the fluid
needle and trigger piston onto the spray
gun body.
5. Pressurize the spray gun and test.
6. Repeat if necessary.
Figure 10
For customer service call 888.389.2732
(continued)
Figure 11
Figure 12
Figure 13
AUTOMATIC
Fluid Seal Nut.
Turn clockwise
to tighten
Fluid Seal Nut.
Turn counter-
clockwise to
loosen
Page 9