- ページ 10

コントローラー 4qd 4QD SeriesのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。4qd 4QD Series 16 ページ。

Motor wiring

Motor polarity

As shown M+ is positive for forward direction. It is
usually easiest to connect the motor up without
regard for polarity and, if the direction is wrong,
reverse it later.

11 Control wiring

The control wiring can all be thin: the control connectors supplied are designed to accept 7/0.2 wires and it is
suggested you use this.
Control wiring does not generally need to be screened, unless it passes close to motor or battery wiring.
There is a fuse in the control circuitry - see section 17.

Pre-wired models

Some samples are supplied with multicore cables for
the controls to help the user with prototype machine
wiring. On these colour coding is:
6 core cable
Green
0v (battery –ve)
Blue
Pot wiper
Red
Pot +ve (max speed)
Black
Reverse
Yellow +12v supply
White
inhibit
4 core cable
Yellow battery +ve
Blue
'Ignition' switch
Red
switched battery +ve
Black
0v spare
Red and Black can be used for battery meter or relay
3 core cable
Red
battery +ve (brake solenoid)
Blue
Brake solenoid, switched
Green
0v

Connectors

Connectors are supplied with the controller. They are
'IDC's which stands for 'Insulation Displacement
Connector'. The reason is that you do not need to
strip the insulation from the wire before using it - you
simply push the wires into the connector and squeeze
it closed in a vice or with a pair of parallel jawed
pliers. This is far quicker and more reliable, therefore
cheaper, than either screw terminals, crimps or
soldered connections.
Page 10

Using several motors

Controllers cannot count! The controller will not be
able to tell if you are using one, two or fifty motors -
all it knows is the load it is being asked to bear,
which is determined by the mechanics (mass, speed
and gradient) not the number of motors.
The simplest way of using several motors is to wire
them in parallel to the motor terminals.
Installed models
locating ridge
red
blue
wiper
pot max
green
black
0v
reverse
white
yellow
ignit'n
+24
View of soldered pins
Bulgin 6 pin
chassis mounting male
Colour
Function
Green
0v to pot
Blue
speed
Red
11.5v to pot
Black
reverse
White

+ignition

Yellow
battery +ve
You must however use the correct wire which is
flexible 7/0.2 (7 strands, each 0.2mm).
Nearest US equivalent: 24 AWG (commonly 7
strands of 32 AWG).
It is available in multicore, ribbon or as individual
wires. Wire which is too thin will not make contact.
Wire which is too thick will damage the tines. Single
conductor (telephone cable) wires will soon break
4QD series controller instructions.
The diagram, left,
shows the pin
connections on the 6
way connector
commonly used
with our controllers.
See also section 11
for a picture of a
'Hand control box
and control lead
connector pin
6 pin
‡ F
6 pin
‡ E
6 pin
‡ D
6 pin
‡ C
4 pin
‡ C
4 pin
‡ D