Use
Before you start
Switch on the appliance at the switched fused connection unit. The appliance is ready for use.
WARNING: Read the instructions before using the appliance.
Functions and settings
• Flame safety device (FSD): Stops the gas supply to the gas hob when the flame goes out.
• Auto ignition.
Injector Table
Gas Category UK & IR
II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
Type of
Type of
gas used
burner
Auxiliary
NATURAL GAS
(Methane)
Semi Rapid
G20
Rapid
LIQUEFIED
Auxiliary
PETROLEUM GAS
Semi Rapid
(Butane)
G30
Rapid
Auxiliary
LIQUEFIED
PETROLEUM GAS
Semi Rapid
(Propane)
G31
Rapid
TRAG10578 - 200000002 - 4 Burner Gas v3d Rv3.indd 13
Injector
Rated
marking
thermal
flow rate
kW
0.72mm
0.95
0.97mm
1.75
1.15mm
2.90
0.50mm
0.90
0.65mm
1.65
0.85mm
2.90
0.50mm
0.90
0.65mm
1.65
0.85mm
2.90
Rated
Reduced
consumption
heat
capacity
kW
91 lt/h
0.28
167 lt/h
0.45
276 lt/h
0.75
65 g/h
0.25
120 g/h
0.40
211 g/h
0.80
64 g/h
0.25
118 g/h
0.40
207 g/h
0.80
13
Gas pressure
rating (mbar)
20
28-30
37
13/06/2017 16:45