- ページ 13

除湿機 BENDIX AD-9siのPDF サービスデータをオンラインで閲覧またはダウンロードできます。BENDIX AD-9si 16 ページ。 Oil coalescing air dryer

BENDIX AD-9si サービスデータ
SYMPTOM
1. Dryer is constantly "cycling"
or purging.
BENDIX
AD-9si
®

TROUBLESHOOTING CHART

CAUSE
A. Excessive system leakage.
B. Defective delivery check valve.
C. Defective governor.
D. Compressor unloader mechanism
leaking excessively.
AIR DRYER
®
A. Test for excessive system leakage. Allowable leakage observed
at dash gauge:
- Single vehicle - 1 psi/minute.
- Tractor trailer - 3 psi/minute.
Using a soap solution, test the vehicle for leakage at the
fittings, drain valves, system valves, and any accessories (i.e.
air suspension). Repair or replace as necessary and retest the
system.
B. Build the system pressure to governor cut-out. Wait 1 minute for
completion of purge cycle. Using a soap solution at the exhaust
of the purge valve, leakage should not exceed a 1 inch bubble
in less than 5 seconds.
If a rapid loss of pressure is found, the following procedure will
determine if the delivery check valve is malfunctioning:
Build the system pressure to governor cut-out and allow a full
minute for the normal dryer purge cycle to empty the purge
reservoir. Switch off the engine and apply and release the brakes
multiple times so that the system pressure reaches governor cut-
in. The purge valve will return to its closed position. Carefully
remove the air dryer cartridge using a strap wrench and then
test for air leaking through the center of the threaded boss by
applying a soap solution to the area. Replace the delivery check
valve if there is excessive leakage (exceeding a 1 inch bubble
in 5 seconds).
Re-grease the seal on the air dryer cartridge before reinstalling.
C. Check governor at both "cut-in" and "cut-out" position for
proper pressures and excessive leakage at the exhaust.
D. Remove the air strainer, or fitting, from the compressor inlet
cavity. With the compressor unloaded, check for unloader piston
leakage. Slight leakage is permissible.
REMEDY
13