- ページ 6
産業機器 dymax BlueWave MX-150のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。dymax BlueWave MX-150 12 ページ。 Ledd spot-curing emitters
dymax BlueWave MX-150 にも: ユーザーマニュアル (16 ページ)
Click here for more details on the Dymax BlueWave® MX-150 LED Emitter - 405nm
Troubleshooting & Maintenance
Problem
BlueWave MX-150
LED does not
produce light
BlueWave MX-150
LED suddenly
stops producing
light
BlueWave MX-150
LED provides only
low-intensity light
8
Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com
Possible Cause
LED intensity adjustment
set to 0% or too low
LED cycle time is set to 0
seconds
Interlock is open
Interface cable
connections loose or
damaged
Trigger setting not
matched to input
LED head is not
connected to the correct
port/channel
Lightguide not inserted
Over-temperature
shutdown was triggered
Footswitch defective
Interlock is open
LED intensity adjustment
set to minimum
Contaminated/dirty lens
optics
• 508-992-6464 | (800) 473-4237 •
23 Centre Street • New Bedford, MA 02740 USA
Corrective Action
Increase LED intensity setting.
0 Seconds sets manual mode
and requires a trigger.
Verify interlock jumpers are in
place. Verify PLC command
structure for PLC mode.
Check connections and
condition of interface cable.
Trigger setting on admin screen
should match the desired input
trigger channel.
Verify that the head is
connected to the desired
port/channel.
Ensure the lightguide simulator
or any lightguides installed with
the unit are fully seated into the
Wolf connector.
Verify alarms.
Activate unit using the front
control panel. Replace the
footswitch if the unit operates
from the front control panel.
Verify interlock jumpers are in
place.
Verify PLC command structure
for PLC mode.
Increase LED intensity setting
on admin settings or I/O input
for PLC mode.
Clean the surface of the lens.
U S E R G U I D E
|
B L U E W A V E M X - 1 5 0 E M I T T E R S
Product data subject to change
without notice.