AB HVLP series
ADJUSTMENT SEQUENCE
1.Lock the gun to the system using the
fastening bracket and orient the
head towards the appropriate
coverage direction.
2.Connect the atomization air, control
air and product piping to the
junctions shown on the previous
page.
3.Screw the handwheel part.
[1007-42] as far as it will go (do not
force when reaching the stop). Act
on the control air. If no drop of
pigment comes out, remove the
control air, and open the handwheel
part. [1007-42] with one click.
Repeat the process until the first
drop appears.
4.Open the handwheel part. [1007-42]
with the necessary clicks to
determine the desired amount of
pigment.
5.Act on the adjustment screw part.
[1007-7]to obtain the desired atomization
range.
10 shots per revolution
6
5
4
aircom.it
7
8
9
10
1
3
2
Instruction Manual - 7
EN