- ページ 7

ペイントスプレー Dyna-Fog Hurricane Ultra 2794のPDF 操作およびメンテナンスマニュアルをオンラインで閲覧またはダウンロードできます。Dyna-Fog Hurricane Ultra 2794 15 ページ。 Ulv/mist sprayer

Dyna-Fog Hurricane Ultra 2794 操作およびメンテナンスマニュアル
Where a high flash point or "no" flash point liquid formulation will ignite far less
readily than a low flash point liquid and for this reason is strongly advocated. The
higher or "no" flash point formulation can ignite if the proper conditions exist. These
conditions are basically two: 1. A sufficiently volume of liquid in the form of fine
particles suspended in the air; and 2. A sufficiently high energy source of ignition.
AEROSOL CONCENTRATION.
3.
acceptable level of liquid in the atmosphere is one gallon per 50,000 cubic feet (2.7
Liter per 1,000 cubic meters). There is a safety margin of at least 5 to 1 in this
figure.
AEROSOL IGNITION.
4.
combustible deposit is laid down, a source of ignition may cause a fire. Sources of
ignition can be gas or oil pilot lights or sparks from electrical controls. Therefore, it
is strongly recommended that all such sources be eliminated by extinguishing all
pilot lights and turning off all unnecessary electric power. To avoid danger of fire or
explosion in an enclosed space, the enclosed volume fogging time and required
formulation volume should be carefully calculated.
PROPER AND IMPROPER USE.
The following rules apply to the operation of this machine:
Read the entire manual before operating the machine and pay particular attention
to all CAUTIONS and WARNINGS.
Store formulation in its original labeled container.
Use an extension cord which is properly rated for voltage, current and length and
which is free from nicks, cracks and other signs of prior abuse. For lengths up to
100 feet (30.5 meters) cord No. 12AWG wire are usually adequate.
Replace damaged or worn electric cord immediately.
Turn the flow valve CLOCKWISE to the OFF position after each spray application
while the motor is still operating to allow clearing of the lines. This will also prevent
a siphon effect if the unit is ever accidentally knocked over with the valve remaining
open.
Always comply with any requirements for protective clothing, goggles, gloves, facial
masks or respirator required by the formulation label.
Ensure that formulation are applied only in strict compliance with the formulation
label as well as local State and Federal regulations.
It has been fully established that an
If a combustible atmosphere is established or a
DO
7