- ページ 9

ヒーター Dyna-Glo Pro LPFA43HのPDF 取扱説明書および操作説明書をオンラインで閲覧またはダウンロードできます。Dyna-Glo Pro LPFA43H 16 ページ。 Propane construction heater

Dyna-Glo Pro LPFA43H 取扱説明書および操作説明書
PROPANE CONSTRUCTION HEATER
Propane is safe to use when properly handled. Careless handling of the Propane gas tank could
result in fire and/or an explosion. Therefore:
• Always keep tank/cylinder securely fastened in an upright position.
• Avoid tipping tank on its side when connected to a regulator since this may cause damage to
diaphragm in regulator.
• Handle valves with care.
• Never connect an unregulated Propane tank to construction heater.
• Do not subject Propane tank to excessive heat.
• Tightly close the gas shutoff valve on the Propane tank after each use.
• The POL fitting must be protected when disconnected from the propane tank.
• Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance.
THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING, GARAGE
OR ANY OTHER ENCLOSED AREA.
Check all gas connections with a soap solution to be sure they are tight and leak proof (see page 7).
• The installation of your heater must meet all local codes and/or gas utility requirements or, in the
absence of local codes, with the Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA
58 and the Natural and Propane Installation Code, CSA B149.1.
• The minimum clearances to combustible construction: Side - 24" (61 cm); Top - 36" (92 cm);
Front - 72" (183 cm); Floor - combustible, must be maintained at all times.
• The hose assembly should be visually inspected prior to each use of the heater. If it is evident that
there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being
put into operation.
• The replacement hose assembly shall be that specified by the manufacturer (Refer to parts list).
WARNING
: Motor and fan must be running before lighting, during operation and shutdown, in
order to prevent a flame-out condition which could result in personal injury or property damage.
1. Connect power cord to a properly grounded three (3) prong 120V, 60Hz, single phase receptacle.
2. Turn gas valve knob clockwise
3. Wait five (5) minutes to clear any gas. Then smell for gas, if you don't smell gas, go to next step.
4. Turn gas supply ON by turning Propane tank valve counterclockwise
5. Push in and turn gas control knob counterclockwise
burner. Keep depressing and turning from OFF
manual piezo ignition systems.
6. Keep the valve knob depressed for at least 30 seconds after lighting the burner. After 30 seconds
release valve knob.
7. If burner does not stay lit, repeat the lighting procedure.
8. When burner is lit, turn gas valve knob counterclockwise
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
PROPANE SAFETY
LEAK CHECKING
LIGHTING INSTRUCTIONS
to OFF
position.
to LOW
.
to "LOW
/ IGN ". This will light the
/ IGN until burner lights for FA43
to desired setting.
8