- ページ 2

防犯カメラ Active Silicon HARRIER H.264のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Active Silicon HARRIER H.264 6 ページ。 Ip camera interface board

Active Silicon HARRIER H.264 クイック・スタート・マニュアル

Evaluation Kit Contents

The Evaluation Kit for the Harrier IP (AS-CIB-IP-001-EVAL-A) contains all the parts needed to evaluate the
Harrier IP Camera Interface Board. Note that the evaluation kit does not include a Harrier IP Camera
Interface Board, FFC cable or camera, these need to be ordered separately.
Please check that you have all the parts listed below:
Multi-region 12V power supply (please fit the adapter suitable for your region)
Power adapter cable (barrel to 4-way JST connector)
Ethernet interface cable (JST connector to RJ45 socket)
Figure 4. Ethernet interface cable
Setting up the Boards
If you have purchased a pre-assembled camera you can skip this step.
1. Connect the Harrier IP Camera Interface Board (SoC board) (J2) to the Ethernet connection board
(J1) using a 24-way 0.5mm pitch double ended (same side contacts) FFC cable. Ensure that the
cable is connected the right way round. For the SoC board (J2) the metal contacts should face
towards the microSD socket. For the connection board (J1), the metal contacts should face the
PCB.
2. Connect the SoC board (J8) to the camera LVDS output using a KEL 30-way microcoax cable.
3. To avoid damage the boards must be securely mounted so that the cables are not strained.
Figure 6. Harrier Ethernet connection board
November 2021
HARRIER H.264 IP CAMERA INTERFACE BOARD
Figure 5. Power adapter cable
Figure 7. Harrier IP Camera Interface Board
(SoC board)
QUICK START GUIDE
Version 1.0 – November 2021
Page 2 of 6