- ページ 6
マルチメーター Dawson Tools DDM450のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Dawson Tools DDM450 9 ページ。
8. Battery Test:1.5V
1.Turn rotary switch to 1.5V battery test position.
2.Connect leads across battery
3.Read measured voltage on the display.
9. Battery Test:9V
1.Turn rotary switch to 9V battery test position.
2.Connect leads across battery
3.Read measured voltage on the display.
10. Non-Contact Voltage Detector:
6
DDM450
1.In any mode, hold NCV button.
2.Move top of meter near voltage source.
3.If voltage is detected, the NCV indicator flashes/buzzer beeps.
4
DDM450
4
DDM450
NCV
9
Specifications
7.
• Operating Altitude: 2000m
• Relative Humidity: 75% max
• Operating Temperature: 0°C~40°C/32°F~104°F (<80% RH)
• Storage Temperature: -10°C~60°C/14°F~140°F (<70% RH)
• Accuracy Temperature: -18°C~28°C/64°F~82°F (<80% RH)
• Temperature Coefficient: 0.1x(specified accuracy)/°C (<18°C or >28°C)
• Sampling Frequency: approx. 3 times/sec.
• Fuse Protection: µA/mA input: FF 600mA H 600V
10A input: FF 10A H 600V
• LCD Display: 3 ¾ digit display (4000 counts)
Power
Supply: 9V battery
•
•
Dimensions
: 150mm×74mm×48mm / 6.3"×2.9"×1.9"
• Weight:
8.9oz/250g
• Safety Rating: CAT III 600V; pollution degree: II
• Safety Standards: IEC61010-1
• Pollution Degree: 2
• Accuracy: ±(of reading + # of least significant digits)
ELECTRICAL SPECIFICATIONS
8.
DC Voltage Measurement
Range
Resolution
400mV
0.1mV
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
• Input impedance: 10MΩ
• Max. input voltage: 600V rms
Accuracy
±(0.5% of reading +2 digits)
±(0.7% of reading +2 digits)
10