水ポンプ Hi-Force HPF207414のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Hi-Force HPF207414 16 ページ。 Electric driven, general duty, medium flow

6.3 Pumps with Solenoid Valves

1. Set the adjustable pressure relief valve (5) if required. See section 6.1 for details.
2. Turn the motor on by pressing the green 'ON' button (1).
3. Press and hold the 'advance' button on the pendant to advance the cylinder. Release the button
once the cylinder has been advanced the desired amount. The cylinder will remain in the load
holding position when the button is released.
4. Press and hold the 'retract' button to retract the cylinder. Release the button once the cylinder has
been retracted.
NOTE: After operation of the press, it is good practice to return the cylinder piston
Inspect the pump for damage after each use.
Change the oil every 500 working hours using high quality ISO46 hydraulic oil.
Before storing ensure the cylinder piston has been fully retracted.
Have the pump serviced regularly by a Hi-Force authorised repair centre.
Operating Instruction Manual:
OM-HPF PUMP-01

7.0 Maintenance

12
From Serial Number:
BS8412