Hi-Force IP Square Drive Torque tools should be serviced and repaired only by authorised
Hi-Force repair centres. The following table gives possible causes and solutions for common problems.
Problem
1. Square drive does not
rotate.
2. Performance drop.
3. Tool vibrates
abnormally.
4. The square drive
continues rotation after
the trigger is released.

11.0 Troubleshooting

TROUBLESHOOTING GUIDE
Possible Cause
a. Trigger (4) not fully depressed.
b. The pressure or capacity of the air
supply in insufficient.
c. Temperature too low.
d. Directional control (5) position is
incorrect.
e. Tool failure.
a. Trigger (4) not fully depressed.
b. The pressure or capacity of the air
supply in insufficient.
c. Directional control (5) position is
incorrect.
d. Insufficient lubrication.
e. Clogged exhaust (8).
f. Tool failure.
a. The tool is not sufficiently
supported between the operator
and the application.
b. Handle (3) not fitted.
c. Socket not properly engaged to the
tool.
d. Worn or broken sockets.
e. Tool failure.
a. Trigger mechanism jammed.
Operating Instruction Manual:
OM-IP-01
Solution
Ensure that the Trigger (4) is fully depressed.
Check the airline pressure and capacity.
Operate in an environment with higher
temperature.
Check the position of the directional control
(5)
Contact your local Hi-Force office.
Ensure that the Trigger (4) is fully depressed.
Check the airline pressure and capacity.
Check the position of the directional control
(5)
Check lubrication See section 5.3
Clean the exhaust (8).
Contact your local Hi-Force office.
Ensure the tool is sufficiently supported.
Fit the handle as per Section 5.2.
Check socket engagement.
Check the sockets for wear and or damage.
Contact your local Hi-Force office.
Switch off the air supply and disconnect once
discharged. Contact your local Hi-Force office.