- ページ 8
ゲートウェイ 6TL YAV90090のPDF マニュアルをオンラインで閲覧またはダウンロードできます。6TL YAV90090 18 ページ。 Ethernet to can gateway
Ethernet to CAN Gateway YAV90090 620090E06
Connectors
X1: CAN
2.5.1 CAN
The CAN connector is a 4-pin Weidmüller 3,5" pitch.
The mating connector is aerial Weidmüller 1690210000
2.5.2 CAN End Jumper
The CAN network ends must be "closed" with a resistor to reduce echoes in signal pulses.
Only in the case that the physical position of the board in the CAN network is in the end
position, the jumper must be placed (Resistor joining CAN H and CAN L).
2.5.3 LAN
Connector RJ45 (22): Suitable for CAT 5&6 Fast Ethernet Cable. Meets IEEE 802.3
standard for 100 Base-T.
The purpose of this port is to configure the device as an Ethernet control.
8
LAN address
settings
SW 1: CAN speed
and address
RUN Led
Pin
Function
1
GND
2
+24V
3
CAN L
4
CAN H
Boot
USB 2.0 port
CAN end
(Factory use)
Resistor
LAN