レーダー Hi-Link HLK-LD303-24GrのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Hi-Link HLK-LD303-24Gr 8 ページ。 Radar module

2、 Technical parameters
Parameters
Trasmit frequency
Antenna style
Working current
Working voltage
Working temperature
Data interface
Data format
Response time
Level output
Detection range
Detection dead zone
Detection accuracy
Product size
3、Data protocol
Communication configuration:
TTL serial port, the default baud rate is 115200, the data bit is 8, the stop bit is 1, and there is no
check bit.
Fixed query command (HEX): 55 5A 02 D3 84
The module defaults to query mode, sending fixed hexadecimal query commands, and the
module reports distance and other data after successful reception.
Communication format:
Uplink data (module sending)
Word
Frame
length Add
threshold
header
Number
2
of bytes
content
55A5
0A
Distance
Reserve Situation
1
1
2
D3
XX
3
HLK-LD303-24G USER MANUAL
Explanation
24.00~24.250GHz
Horizontal angle 43°/vertical angle 116°
79mA(5V)
DC5V~12V
-20~+60℃
TTL serial port
115200,8,n,1
≥60mS
Reserved
10~350cm
10cm
5cm
39*29mm
Signal
strength
1
1
XX
X
Fretting
Radar
off
2
1
1
X
X
X
X
check
1
XX