- ページ 7

換気フード Gaggenau AC250190のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Gaggenau AC250190 12 ページ。

Gaggenau AC250190 取扱説明書

Intermittent mode

Intermittent mode automatically switches on the
extractor hood for 10 minutes every hour. The function
switches itself off again after 24 hours.
This function can be activated from the control panel or
using the remote control.
Note: If intensive mode or the run-on function has been
activated, the intermittent function will not be available.
Switching on intermittent mode from the control
panel
ÿ
@
1
Press the
and
appear on the display.
@
A
2
Press the
or
button to set a different fan
setting.
ÿ
@
3
Press the
and
confirm the fan setting for intermittent mode.
Switching on intermittent mode using the remote
control
g
1
Press the
button.
@
A
2
Press the
or
button to set a different fan
setting.
g
3
Press the
button to confirm the fan setting for
intermittent mode
Note: Pressing any of the buttons (except the button for
the light) will deactivate intermittent mode.

Run-on function

The run-on function allows the extractor hood to
continue running for a few minutes after it has been
switched off. This eliminates any remaining cooking
smells. The extractor hood will then switch itself off
automatically.
Switching on
Note: If intensive mode has been activated, the run-on
function will not be available.
ž
Press the
button on the control panel or on the
remote control.
The fan will run for 10 minutes at setting
flash on the display during this time. Then the fan will
switch itself off automatically.
Switching off
ž
Press the
button on the control panel or the extractor
hood's remote control.
This will deactivate the run-on function immediately.
buttons at the same time.
buttons at the same time to
will appear on the display.
and a dot will

Lighting

@
Press the
=
button on the remote control.

Saturation signal

The following will happen when the filters are saturated:
ª
The
symbol appears in the display: Clean the
metal grease filter
'
The
symbol appears in the display and a signal
sounds: Replace the activated charcoal filter
will
See the "CleanAir air recirculation module" printed
supplement or the section entitled~
maintenance" on page 8
Resetting the saturation signal
When the fan is switched off, the signal is also switched
off.
The relevant filter(s) should be cleaned now if you have
not already done so.
Switching over the appliance to air recirculation
1
Switch off the appliance.
2
Press the
the same time until the
release the buttons.
'
The
indicator will go out shortly afterwards. The
electronic controller has now been switched over to air
recirculation mode.
Switching over the appliance to air extraction
Note: The default setting is air extraction mode.
1
Switch off the appliance.
2
Press the
the same time until the
release the buttons.
ª
The
indicator will go out shortly afterwards. The
electronic controller has now been switched over to air
extraction mode.
Operating the appliance
button on the control panel or the
ÿ
ž
and
buttons on the control panel at
'
indicator lights up. Then
ÿ
ž
and
buttons on the control panel at
ª
indicator lights up. Then
en
"Cleaning and
7