Fig. 9
Fig. 10
Fig. 11
Worktop height ≥ 90 cm,
variable position of the fan module
– Saw out the base plate in the built-in cabinet for
the fan module.
– Place the fan module in the base cabinet.
Refer to the operating instructions of the fan
module for details of how to install it.
– Using a flexible aluminium pipe (DN 125),
connect the pipe connection piece to the fan
module.
– Now lower the hob ventilator into the worktop.
Make sure that the engaging lugs on the
appliance lie exactly on the clamping springs.
Press the appliance firmly into the worktop.
The engaging lugs on the appliance "snap" into
the clamping springs.
– At the front, fix the hob clamping element onto
the worktop from below until the appliance is
pressed on evenly (Fig. 11). If the worktop is
less than 36 mm thick, place the hob clamping
element under it.
– Cut off protruding sealing tape.
13