GEL LEAD ACID TYPE.
DO NOT USE GATES BATTERY
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
BATTERY CAPACITY FOR EMERGENCY
STANDBY USE AT LEAST 4 HOURS.
–
BLACK
CHARGING
BATTERY
VOLTAGE
+
RED
12V, 4AH
13.8VDC
OR 12V, 1.2AH
CONNECTOR TABS
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER OUTPUT AND REMOTE
CONSOLE CURRENTS.
USE UL LISTED
LIMITED ENERGY
1
2
CABLE FOR ALL
CONNECTIONS
FOR COMPLETE
INFORMATION, SEE
INSTRUCTIONS
N5672VS
TO 110VAC
UNSWITCHED
OUTLET (24HR)
PLUG-IN TRANS-
FORMER
16.5VAC, 25VA
(e.g. ADEMCO
No. 1321/TF2.
USE No. 1321CN
IN CANADA
+
ALARM OUTPUT
10.5-13.8VDC, 2A MAX.
(600mA MAX FOR UL USAGE,
INCLUDING AUX. POWER)
STEADY FOR BURGLARY/PANIC,
PULSING FOR FIRE (e.g. USE ADEMCO
No. 702 OR 719 SIREN, OR 12V BELL)
CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM
HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED
ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAV-
ING JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT
BE CONNECTED TO A POLICE EMERGENCY NUMBER.
FUSE
FOR REPLACEMENT,
USE SAME VALUE
3A
BATTERY
(e.g. No. 90-12)
+
–
BLK
RED
GRN
YEL
3
4
5
6
7
8
–
+
AUX. POWER
OUTPUT
10.5-13.8VDC
500mA MAX.
INTERRUPTS
FOR FIRE
ALARM RESET
NOTE:
CONSOLE
CURRENT MUST
BE INCLUDED IN
AUX. CURRENT
DRAIN
CALCULATIONS
OHMS
REMOTE
• MAXIMUM LOOP RESISTANCE (EACH ZONE) 300 OHMS (PLUS EOLR)
–
CONSOLE
• RESPONSE, ZONES 1-6: 300-500MSEC
• ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR FAST RESPONSE TO AN
No. 4127: 20mA
OPEN: 10MSEC MAX
No. 4137AD: 60mA
• ZONE 5 CAN BE PROGRAMMED FOR USE AS A FIRE ZONE. SEE DIAGRAM
No. 6127: 20mA
No. 6128: 30mA
No. 6137: 85mA
OR
No. 5330: 105mA
NOTE: MULTIPLE CONSOLES
MAY BE USED, BUT EACH 5330
CONSOLE MUST BE ON AN INDI-
VIDUAL HOME RUN. USE MAX.
OF 220FT. OF #22 WIRE OR 550
FT. OF #18 WIRE.
No. 4110DL SUMMARY OF CONNECTIONS
OPTIONAL
No. 4116
ARMING/DISARMING
KEYSWITCH
(SINGLE LED, LOCKSWITCH,
TAMPER)
9
10
11
12
13
1000
1000
1000
1000
OHMS
OHMS
OHMS
EOLR
EOLR
EOLR
EOLR
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT
CAUSE HARMFUL INTERFERENCE, (2) IT MUST ACCEPT ANY INTER-
FERENCE THAT MAY CAUSE UNDESIRED OPERATION.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.
WARNING:
WEEKLY TESTING IS REQUIRED TO ENSURE
PROPER OPERATION OF THIS SYSTEM.
AUX PWR
+
5
OUTPUT
BLK
-
TERMS
4
+
-
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
+
+
HEAT
–
DETECTOR
-
ZONE 5
(IF PROGRAMMED FOR FIRE)
14
15
16
17
18
19
TIP
RING
TIP
(BROWN)
(GRAY)
(GREEN)
HANDSET
PHONE LINE
TELEPHONE WIRING
(VIA RJ31X* JACK DIRECT
CONNECT CORD)
*IN CANADA, CA38A JACK
DOC LOAD NO.: 3
WARNING:
TO PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE LINE
1000
1000
OHMS
OHMS
AT TELCO JACK BEFORE
EOLR
EOLR
SERVICING THIS UNIT.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PRO-
TECTION ASSOCIATION'S STANDARD 74 (NATION-
AL FIRE PROTECTION ASSOC., BATTERYMARCH
PARK, QUINCY, MA 02269). PRINTED INFORMATION
DESCRIBING PROPER INSTALLATION, OPERATION,
TESTING, MAINTENANCE, EVACUATION PLANNING
AND REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.
+
RED
–
EOL
POWER
SUPER-
VISION
VIOLET
RELAY
MODULE
•
A77-716B
1000
OHMS
•
EOLR
20
21
LOCATED AT
LOWER RIGHT CORNER
OF CIRCUIT BOARD
RING
(RED)
INCOMING
EARTH GROUND
SEE INSTRUCTIONS
FOR PROPER GROUNDING