- ページ 9
コントローラー Active-semi PAC5222EVK1のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Active-semi PAC5222EVK1 10 ページ。 Power application controllers
PAC5222EVK1 S
The setup for the PAC5222EVK1 evaluation module requires up to four simple connections.
1. Connect the VIN power source via spade tab connectors VIN and GND. As VIN power is applied, the
LED D7 will light up. Once VIN voltage goes above 8V, the PAC5222's Multi Mode Power Manager
will be engaged and the VSYS (5V) regulator will be enabled. This event will result in LED D16
lighting up.
2. Connect the 3 Phase BLDC/PMSM motor via space tab connectors PHASE U, PHASE V and PHASE
W.
3. If Serial Communications are desired, connect the USB to UART module 4 pin connection to J7.
4. For debugging/programming, connect a suitable USB SWD module to J1 by using a standard 4 wire
cable.
ETUP
Figure 4: PAC5222EVK1 Evaluation Module Connections
-
9
-
Rev 1.0 August 2018