扇風機 HiB SELV Hush ChromeのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。HiB SELV Hush Chrome 4 ページ。 Wall mounted fans
Electrical Connection
1) Ensure the domestic electrical mains supply to
which the fan is being connected is turned off.
This product is designed to be connected to
an on/off switch outside the bathroom, or to a
ceiling mounted pull cord switch.
2) Hush Only: Remove the front panel and
protective cover (4). Pass the power wire
through the hole in the rubber plug (beneath
protective cover) at the fan casing flange.
3) Breeze Only: Remove the protective grille.
Cut out blanking plug of electrical access
point (3) and lead the power supply cords
through the hole.
4) Make the electric connections according to
the relevant wiring diagram below.
5.
Connect the electrical wiring to the motor
according to the diagram below.
- Switching fan and luminaire on/off
together with one switch.
+
-
Fan
Transformer
6.
Fix the fan to the wall/ceiling using 4
screws.
7.
Replace the cover and protective grille.
L
230v
N
Supply
Ceiling mounted...
For ceiling mounting follow procedure for wall
mounting making sure ducting isn't mounted
vertically to the outside. This is to ensure
moisture doesn't come back into the motor.
Maintenance
In the event of a fault, please check the in-line
fuse located inside the connection box.
Fan maintenance is to be performed only after
the fan is disconnected from the mains power
supply. Maintenance means periodic clearing
of the surfaces from dust and dirt.
In order to remove the fascia for maintenance,
please remove the small retaining screw and
gently prise the fascia away from the casing.