∗89
Event Log Full Report Code
See box above *59 for report code entries.
∗90
Event Log Enables
NOTE : System messages are logged when any non-zero
selection is made.
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close. Example: To select "Alarm/Alarm Restore",
and "Open/Close", enter 9 (1 + 8); to select all, enter #15.
∗91
Option Selection
Multiple choice example: for AAV (4) + Exit Delay restart (8) enter # + 12.
0 = None
4 = AAV UL: must use ADEMCO UVCM module
8 = Exit Delay Restart/Reset UL: must be disabled
SIA Installations: Exit Delay should be enabled.
∗93
Reports in Armed Period Per Zone
( Also known as Swinger Suppression)
0 = Unlimited Reports; 1 = 1 report; 2 = 2 reports
UL: must be "0"
DOWNLOAD INFORMATION
∗94
Download Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits, 0–9; #+11 for ' '; #+12 for '#'; #+13 for a
2-second pause. Do not fill unused spaces. If fewer than 20
digits, exit field by pressing . To clear entries, press 94 .
UL: downloading may be performed only if a technician is at
the site.
∗95
Ring Count For Downloading
NOTE: Do not enter "0" if using 4285/4286 Phone Module.
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
∗96, *97
Initialize/Reset Defaults
These
(
are commands, not data fields. See page 2
∗98, *99
Exit Commands
(
These
are commands, not data fields. See page 2
PAGER OPTIONS
∗160
Pager 1 Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = ' '; #+12 = '#';
#+13 = 2-second pause.
∗161
Pager 1 Characters
|
|
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' '; #+12 = '#'; #+13 = 2-second pause.
∗162
Pager 1 Reporting Options
Select from the following options:
0 = no reports sent
1 = Open/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and open/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9, and
open/closes for all users
∗172
Pager Delay Option For Alarms
0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes
This delay is for ALL pagers in the system.
NOTE: The delay does not reset for new alarms occurring
while an existing pager delay is in progress.
[00]
[3]
[8]
[1]
[15]
|
|
|
|
|
|
|
|
|
[0]
[3]
MISCELLANEOUS SYSTEM FIELDS
|
∗177
Device Duration 1, 2
(used in *80 Menu mode-Device Actions 5/6)
0 = 15 seconds
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
∗181
60 Hertz AC Operation
0 = 60 Hz; 1 = 50 Hz
CONFIGURABLE ZONE TYPE OPTIONS
∗182
Configurable Zone Type 90
1
2
3
Enter the appropriate value for each entry, 1-10, based on
the charts provided on the next page. Each entry is the
sum of the values of its selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14,
#+15=15).
UL: Do not configure zones as a fire alarm or UL burglar
alarm zone.
∗183
Zone Type 90 Report Codes
IMPORTANT: Use existing Contact ID® codes, if
appropriate, or define unique codes in CID code range
750-789. See note in installation instructions.
90 ALARM ID: XXX
TROUBLE ID: XXX
Enter the desired 3-digit Contact ID® report codes for
alarms and troubles occurring on zones assigned to this
zone type. Enter the codes sequentially (all 6 digits). When
entering digits, [#] moves cursor back, [∗] moves forward.
Press [∗] when done to continue.
KEYPAD OPTIONS
(Options for keypad 1, address 16 are set by the factory and cannot
be changed.)
NOTE: Each keypad must be assigned a unique address.
)
Keypads programmed with the same address will give
unpredictable results.
∗190
)
Keypad 2 Device Address 17
Enable: 0 = disabled; 1 = enabled
Sound: 0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = Suppress chime beeps only
3 = suppress arm/disarm, E/E, and chime beeps
∗191
Keypad 3 Device Address 18
∗192
Keypad 4 Device Address 19
∗193
Keypad 5 Device Address 20
∗194
Keypad 6 Device Address 21
∗195
Keypad 7 Device Address 22
∗196
Keypad 8 Device Address 23
∗197
Exit Time Display Interval
0 = no display; 1-5 = seconds between display refresh
∗199
ECP Fail Display
0 = 3-digit display ("1" + device address)
1 = 2-digit fixed-display as "91"
– 5 –
[0] [0]
6 = 2-1/2 min
#+11 = 7 min
7 = 3 min
#+12 = 8 min
8 = 4 min
#+13 = 10 min
9 = 5 min
#+14 = 12 min
#+10 = 6 min
#+15 = 15 min
4
5
6
7
[0] [0]
Enable Sound
Enable Sound
[0] [0]
[0] [0]
[0] [0]
[0] [0]
[0] [0]
[0] [0]
1
2
[0]
8
9
10
[0]
[0]