- ページ 3

池のポンプ HIBLOW HP-10のPDF マニュアルをオンラインで閲覧またはダウンロードできます。HIBLOW HP-10 5 ページ。

HIBLOW HP-10 マニュアル
HP- 30/40/50
STEP
STEP
FITTING CHAMBER BLOCKS
4
4
Fit the actuating rod by aligning it with the groove 
and tighten U-lock nut and flat washer by the nut 
driver. 
●Use new U-lock nut and washer, otherwise, U-lock nut 
may work loose and cause malfunction.
STEP
STEP
5
5
Insert the actuating rod into the machine body. Be 
sure  to  fit  the  positioning  boss  on  the  diaphragm 
base into the concave part of the frame stay. 
Secure  the  diaphragm  mounting  block  on  the 
other  side  and  tighten  washers  and  U-lock  nuts 
with the nut driver. 
Make  sure  that  gap  between  the  actuating  rod 
and the electromagnets is even.
STEP
STEP
6
6
Mount  the  casing  block  with  screws  (4screws  on 
each side). 
And insert L-tube into the nozzle of casing block. 
Complete the other casing block at the same way.
STEP
STEP
7
7
Install the sound absorber. (HP-50) 
●Be  extremely  careful  not  to  pinch  the  Sound  Absorber 
in the Upper Housing. 
Place the upper housing back on body. 
Fasten it with the bolts. 
Then, place the filter and filter cover on the upper 
FILTER CLEANING AND
housing.  (Refer  to
REPLACEMENT
)
REPLACING THE CHAMBER BLOCK
3