- ページ 9
池のポンプ HIBLOW hp-120のPDF マニュアルをオンラインで閲覧またはダウンロードできます。HIBLOW hp-120 9 ページ。
HIBLOW hp-120 にも: 取扱説明書 (13 ページ)
HP- 100 / 120
STEP
STEP
FITTING THE ELECTROMAGNET
4
4
Mount new the electromagnets in the unit.
Tighten up nuts with nut driver.
STEP
STEP
5
5
Install the SP switch to the frame with the screws.
●Be careful of the direction of switch lever. (Refer to the
pictures)
STEP
STEP
6
6
Insert the wire into the silicon tube, and tie up in a
bundle.
Strip the coating off each wire.
(5-7mm from the end)
Connect the wires to the terminals.
Solder the wires to the terminals.
The wire requires a soldered connection.
STEP
STEP
7
7
This completes the electromagnet replacement
procedure.
REPLACING THE ELECTROMAGNET
9