Remove one of the diaphragm mounting blocks from 
the  actuating  rod  and  pull  out  the  other  diaphragm 
mounting block with the rod. After that, separate the 
diaphragm mounting block and the rod. 
●When pulling out the rod, be sure not to catch the rod
projection on the lever of the SP switch.
●If the pump stops automatically, the safety pin must be broken to prevent any
further damage to the pump. Be sure all broken pieces are removed from the
unit.(See Step 8)
STEP
STEP
FITTING THE CHAMBER BLOCKS
5
5
Fit the actuating rod by aligning it with the groove 
and tighten U-lock nut and flat washer by the nut 
driver. 
●Use new U-lock nut and washer, otherwise, U-lock nut
may work loose and cause malfunction.
STEP
STEP
6
6
Insert the actuating rod into the machine body. Be 
sure  to  fit  the  positioning  boss  on  the  diaphragm 
base into the concave part of the frame stay. 
Secure  the  diaphragm  mounting  block  on  the 
other  side  and  tighten  washers  and  U-lock  nuts 
with the nut driver. 
Make  sure  that  gap  between  the  actuating  rod 
and the electromagnets is even.
STEP
STEP
7
7
Mount  the  casing  block  with  screws  (4screws  on 
each side). 
And insert L-tube into the nozzle of casing block. 
Complete the other casing block at the same way.