HP- 150 / 200
CAUTION
! 
●Be sure to unplug the pump unit. 
●Replace the diaphragms and the valves with new ones at least once a year to one and 
a half year regularly in order to maintain their initial performance. 
●For  chamber  block  replacement,  be  sure  to  change  both  chamber  blocks  at  the  same 
time. 
●The  rod  employs  powerful  permanent  magnets.  Therefore,  be  sure  to  remove  your 
watch and any other precision machines before operation as they may be affected by 
the strong magnetic force. 
●Do not put the actuating rod close to a magnetic card, magnetic disk or other magnetic 
media as the data may be destroyed.
STEP
STEP
REMOVAL OF THE CHAMBER BLOCKS
1
1
To remove the upper housing. 
(Refer to  REMOVING UPPER HOUSING ) 
Remove the sound absorber.
STEP
STEP
2
2
Pull out the L-tube from the casing block.
STEP
STEP
3
3
Remove  the  4  screws  holding  the  chamber  block 
and the casing block. 
(4 screws on each side)
2
REPLACING THE CHAMBER BLOCK