- ページ 9
インターホン・システム Automatic Solutions ABのPDF インストレーション&ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Automatic Solutions AB 17 ページ。 Gsm intercom system
The table below show the complete list of features in the cellular part of the intercom.
TIP: Programming messages below must begin with *12*1234# (if 1234=default passcode)..
Parameter
Description
01????#
Change programming password
Change access control password (SMS control of relays, or non-stored
02????#
numbers can call intercom & enter code to activate output 1).
Change monitoring mode password (user can call the intercom, enter this
03????#
pass code to listen in and speak)
1n????#
Store dialling out numbers. (n = 1, 2 or 3 position)
1n*#
Delete a dial out number. (n = 1, 2 or 3)
3?#
Speaker volume. Where ? = 1-3. 1 = lowest, 3 = highest.
4?#
Microphone volume. Where ? = 1-3. 1 = lowest, 3 = highest.
51?#
Relay time. ? = seconds, 1-9999.
52??#
Calling time - adjust this to avoid voicemail picking up a call (10-99 secs)
53????#
Talking time. 005-999 seconds. Must be 3 digits.
Max monitoring time (for listen in mode when calling the intercom) 00-60
55??#
mins. 00 = no limit.
Store a service number to receive a scheduled call or SMS from the unit
77number#
and prevent inactive SIM being turned off by provider.
Set the time schedule for the intercom to make a scheduled call or SMS
57??#
to the service number. 00-60 day time schedule. 00 = no call or SMS.
58?#
Choose between scheduled call or scheduled SMS. 1 = SMS. 2 = call.
77*#
Delete the stored service number
71???#
Stores country code.
72number#
Store caller ID number. Max 14 digits. Only last 6 digits compared.
73number#
Delete caller ID number. (number = phone number to be deleted).
73*#
Delete all caller ID numbers
Service & diagnostic messages (no passcode required for these!)
*20#
Check reception level 1-31 (no passcode needed)
*21#
Check stored numbers. O = dial out number. I = dial in number. E = end
*22#
Check input status and relay status. (No passcode needed)
999#
Send with passcode string to clear all programming.
P a g e
| 9
GSM unit complete list of parameters
Changing pass codes
Dial out numbers
Volume controls
Scheduled service calls
Caller ID features
Restore Defaults
Timings
Default
1234
5678
1212
N/A
N/A
3
3
1 sec
20 secs
60 secs
10 mins
N/A
00
1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A