Model 295F and 295W Clean Phone™ Telephone

Programming Instructions

Before you begin programming, determine whether you will be programming locally or remotely. This
way, you can be clear on the steps you will take and the passwords you will need to complete the
programming.
Key
Sequence
Function
Reset the unit
#00
to the factory
codes
(Defaults)
Input the
DD...*N
telephone
numbers for
one or both
auto-dial
buttons
Set the auto-
#100N
dial delay time
d:\standard ioms - current release\42004 instr. manuals\42004-146h.doc
11/05
Programming Table
Description
Resets the unit to the codes programmed at the
GAI-Tronics factory.
Assigns a user-supplied telephone number to
either auto-dial button. DD... represents the
user-supplied telephone number, which can be up
to 16 digits in length. N represents the desired
auto-dial button number (1 or 2).
To store * or #, enter the digits twice in
succession. To force the unit to wait for a second
dial tone, enter *# in the appropriate place in the
dialing sequence.
For Example: To assign the police emergency
number 911 to Auto-dial 1, enter 911*1.
If you must dial 9 to get an outside line, using
the above example, enter 9*#911*1.
The auto-dial delay time is the amount of time
the unit waits before dialing the programmed
telephone number for the auto-dial feature.
Available time delay options are 2 through 9
seconds.
N
: A three-second auto-dial delay time is
OTE
recommended. For Example: For a three-second
auto-dial delay time, enter #1003.
Pub. 42004-146H
11 of 17
Page:
Default
Settings
• No auto-dial 1
number;
• No auto-dial 2
number;
• Auto-answer
after 3 rings;
• Remote
password
0 2 9 5;
• DTMF dialing;
• Dial-tone
disconnect
disabled
No numbers
10 seconds