S.M.A.R.T. E
P
XTERNALLY
Call Timeout
The call timeout feature is used to limit the maximum duration of a call. The call timeout can be any
duration between one minute and 4 ½ hours. The duration is set in ½ second increments and the valid
range is from 120 to 32,400. To determine the value associated with a specific time duration, see the
example below.
*37
Data transfer command
<120~32400> Call duration (120 to 32400 ½ seconds) – See example below.
#
End of string indicator
Example:
To determine what to enter for the call timeout duration, multiply the desired time limit, in minutes, by
120. For example, to determine the call duration entry for a call timeout of five (5) minutes, do the
following:
5 minutes × 120 = 600
To enter a call timeout duration of five (5) minutes, enter the character string *37600#.
When the call timeout duration has been successfully entered, the phone returns a system-generated
DTMF check-digit.
Command:
*1
<
>#
NN
CHARAC
*37<120~32400>#
*821
*921
*99
d:\standard ioms - current release\42004 instr. manuals\42004-377c.doc
08/06
ADA-C
OWERED
OMPLIANT
Table R-1. Basic Programming Commands
Factory
Description:
Default:
N/A
Write Memory NN (11-13) with characters (up to 24)
Write Call Timeout (120-32400 × ½ sec).
840
Factory default is 840, or 7 minutes.
N/A
Turn on the relay output (OUT1)
N/A
Turn off the relay output (OUT1)
N/A
End programming call. The S.M.A.R.T. phone hangs up.
E
P
MERGENCY
HONES
PUB. 42004-377C
14 of 18