- ページ 11
エンクロージャー GAI-Tronics 707-001-EXのPDF メンテナンス・マニュアルをオンラインで閲覧またはダウンロードできます。GAI-Tronics 707-001-EX 13 ページ。 Smart series hazardous area speaker amplifier enclosure
Pub. 42004-703L2A
11 of 11
Model 707-001-EX-F07045 SmartSeries Hazardous Area Speaker Amplifier Enclosure
Page:
Specifications
Construction/finish................................................................................. Cast aluminum/gray polyurethane
Mounting............................................................... Wall or column, four 1/2-inch mounting feet with slots
Connections ...............................................................................Internal screw-type barrier terminal blocks
Dimensions.......................................... 15.25 H × 15.25 W × 9.375 D inches (387.4 × 387.4 × 238.1 mm)
Temperature range (operating and storage)........................................... (-4º F to +140º F) -20º C to +60º C
Shipping weight ............................................................................................................. 75 lbs. (34.02 kg)
Enclosure............................................................................................................................. IP66/Type 4X
Approvals
ATEX Certified ...............................................................................................ll 2 G Ex d [ib] IIB + H
T6
2
Applicable standards......................................................... EN 50014:1997, A1+A2:1999, EN50020:2002,
EN 60079-0:2006 and EN 60079-1:2004
CE Mark ...........................................................Complies with Low Voltage Directive 73/23/EEC, and the
EMC Directive 89/336/EEC amended by the Directive 93/68/EEC.
Certificate No. DEMKO 05 ATEX 0526157X
Notified Body Id No. 0539
UL International DEMKO A/S
Lyskear 8
DK-2730 Herlev
Denmark
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-703l2a.doc
11/07