iCLASS Reader Models bio500, RWKL550 & RWKLB575
PARTS INCLUDED
1 - iCLASS LCD Keypad Reader with optional Bio
1 - Installation Manual
2 - #6-32 x .25" x Phillips machine screws
3 - #6-32 x .375" Phillips self-tapping machine screws
2 - #6 x 1.5" Phillips sheet metal screws
2 - #6-32 x .375" Spanner security screws
1 - 10 Position Phoenix Plug
1 - 8 Position Phoenix Plug
1- Foam Gasket
Recommended:
Up to 10 wire splices
Security Tool (for security screw) HID 04-0001-03
Cable, 9 conductor, 22 AWG, shielded (Wiegand)
Linear 12 VDC, 1 A Power Supply
Cable , 6 conductor, 22 AWG, shielded (Serial)
Metal or plastic junction box
Magnetic Tamper switch - Ademco 945T, Sentrol
1038T, GRI 100T or 110T or Aleph DC-2531
Description
RWKLB575
The bioCLASS range is intended for indoor use only and should never be mounted on an exterior wall.
INSTALLATION
1- Install Tamper Switch
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm system.
Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
An ASSA ABLOY Group company
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – [email protected]
iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2
RWKL550
Electrical Back Box

SPECIFICATIONS

Reader Input Voltage:
Current Range:
Cable distance to Host:
16 Gauge Wire
20 Gauge Wire
Op. Temperature:
Open collector output:
Standards:
Read/Write capability in ISO 15693 mode with HID iCLASS
credentials.
Read/Write capability in ISO 14443B mode with HID iCLASS
16KS.
Read capability of CSN/UID in ISO 14443A mode with HID
rd
Mifare and other 3
party Mifare credentials.
Page 1 of 4
9-12 VDC
350 mA standby / 520 mA peak.
50 ft (15 m) max – RS-232.
4000 ft (1216 m) max – RS-485
500 ft (152 m) max – Wiegand
200 ft (60 m) max – Wiegand
32 °F - +113 °F (0 °C – +45 °C)
Sink – 40 mA, source – 1 mA.
bio500
Wall Surface