- ページ 5
カードリーダー HID pivCLASS RP10-HのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。HID pivCLASS RP10-H 8 ページ。
I N STALLATI ON GUI DE
4
Power & Testing
Contactless Models
Contact Models
Note:
With a keypad reader operating as 26 bit emulation, upon power up you have 5 seconds to enter the Facility Code followed by #.
If unsuccessful, the reader LED displays solid Red. Power-cycle the reader and retry entering the Facility Code.
The Facility Code needs to be manually entered as 3 digits (for example, if the Facility Code is 10, enter 0-1-0-#).
SE readers only use Facility Codes between 1-255. There is no default Facility Code.
Once the Facility Code has been entered, the LED will display Violet and then to a final Red. Then power-cycle the reader.
When using a keypad, if there are 2 short beeps after entering your PIN, the reader does not have a Facility Code configured yet.
In this event, an Administrator will need to power-cycle the reader and enter the Facility Code before the reader will accept your PIN.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
h id g l o b a l.co m
pivCLASS
Turn on power
An ASSA ABLOY Group brand
R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
Test card
RPKCL40-P, RKCLB40-P