WIRING DIAGRAM
Black - Hot
Green - Ground
White - Neutral
OPERATING INSTRUCTIONS
•
Move switch up to turn on the fan and light
•
Move switch down to turn off the light. The fan will continue to run for a pre-set DELAY time (unless manually can-
celed)
•
To cancel DELAY time for the toggle version, turn the switch off and back on again within three seconds. Within
another three seconds, turn the switch off and the fan will shut off canceling the DELAY for that use. For the Rocker
version, simply turn the switch off again after use.
•
DELAY will not activate until the light/fan has been on for at least 10 seconds
•
The fan will automatically come on once per hour for the pre-set VENTILATION time.
OPERATION
The SmartExhaust™ has a microprocessor in it that reads the two settings dials. If for example the VENTILATION dial is
set to 20 minutes/hour, the micro- processor subtracts 20 minutes from 60 minutes and determines it needs to come
on 40 minutes into the hour and run for the remaining 20 minutes of that hour.
Now if the DELAY dial is set to 10 minutes and someone uses the bathroom for 5 minutes, the microprocessor will keep
track of the 5 minutes of use. Then when the person leaves after 4 minutes and turns the light switch off, the micro-
processor will keep the fan on for 10 more minutes of the DELAY setting. This will add up to 14 minutes of total fan run
time for that hour. The microprocessor will now subtract the 14 minutes of manual and delay time from the required 20
minutes of VENTILATION time and come up with 6 minutes needed to run at the end of the hour. Now 54 minutes into the
hour the fan will come on and run for 6 more minutes. Resulting in 20 minutes of total run time that hour.