- ページ 7

コントローラー HID Vertx CS V100のPDF クイック・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。HID Vertx CS V100 9 ページ。

HID Vertx CS V100 クイック・インストール・マニュアル
VertX V100 (CS) Quick Installation Guide
Output
number
5
6
7
8
9
10
11
12
6. Input Connections – Input connections are used for a combination of specific functions such as
Request-to-Exit (REX), Door monitor, etc. They can also be used for general purpose monitoring.
Connect one side of the switch or contact to the + (plus) lead and the other to the – (minus) lead. The
following table shows where the inputs are located. Pin numbers shown on the cover use the
convention +/–.
The default REX switch configuration is normally open (NO) unsupervised (no EOL resistors), while the
default door switch (DS) configuration is Normally Closed (NC) unsupervised (no EOL resistors). All
other input points are defaulted for NO switches and are unsupervised (no EOL resistors).
Any input can be configured as a supervised input. They can be configured for resistor values of 1K –
6K Ohm. The setup of supervised inputs should be done during configuration of the VertX units via the
central station automation software (host) or using the Calibrate Input tool explained in the HID VertX
V1000 Quick Installation guide.
Example: Input 1, V1000 is: P14 Pin1 is + and Pin 2 is -.
The default input will be all:
Input
Number
1
2
3
4
August 2005
V2000
V1000
V2000
V1000
P2 Pins 1/2
P14 Pins 1/2
Door Monitor
P2 Pins 3/4
P11 Pins 4/3
REX Input
P5 Pins 4/3
P7 Pins 8/7
Door Monitor
Tamper
P5 Pins 2/1
P7 Pins 6/5
REX Input
AC Fail
2005 © HID Corporation. All rights reserved.
V100
V200
Supervised inputs can be configured for:
V100
V200
P2 Pins 1/2
P1 Pins 1/2
Door Monitor
P2 Pins 3/4
P1 Pins 3/4
REX Input
P5 Pins 4/3
P1 Pins 5/6
Door Monitor
P5 Pins 2/1
P1 Pins 7/8
REX Input
V300
P2 Pins 4/5/6
P2 Pins 7/8/9
P4 Pins 9/8/7
P4 Pins 6/5/4
P4 Pins 3/2/1
P5 Pins 9/8/7
P5 Pins 6/5/4
P5 Pins 3/2/1
V300
P6 Pins 2/1
P3 Pins 1/2
P7 Pins 8/7
Tamper
P7 Pins 6/5
AC Fail
Page 7 of 9