- ページ 8
録音機器 Gainlab Audio GLA-TC2のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Gainlab Audio GLA-TC2 13 ページ。
Gainlab Audio GLA-TC2 にも: 校正マニュアル (18 ページ)
INTERVENTION - THRESHOLD
if the instrument cluster mode
toggle switch is set to the up
position. In this case, the home
position of the instrument cluster is
at 0 and shows the degree of signal
level reduction to the left (in the
negative direction) per dBu unit.
A f t e r s w i t c h i n g b e t w e e n t h e
LOCOMP and HICOMP positions, it
may be necessary to readjust the threshold level and time constants.
Due to the nature of the equipment, the higher the gain reduction value, the higher
the compression ratio. To adjust the threshold level, turn the knob labeled
THRESHOLD clockwise to set the lower threshold level, or turn the knob
counterclockwise to set the higher threshold level.
CHANNEL LINK/UNLINK
The Dictator Dual Mono is set to A-B channel mode by default. In
such cases, the aim is for the right and left channels to run together
as much as possible. However, in certain situations, it may be
advantageous to eliminate the coexistence of the two channels. In this
case, it is possible to separate the auxiliary circuits of the device. To
separate the auxiliary circuits, move the switch right and check
on the lower indicator lights that the compressor is in the
desired operating condition. Move the switch left to return linked mode.
DICTATOR DUAL MONO VARI-μ
The intervention threshold level, THRESHOLD,
determines the signal level at which the dynamics
controller starts compressing.
intervention can be manipulated by the operator by setting
the time constants discussed above, which has a
significant influence on the nature of the sound. The
extent of the interference on the two VU meters can be
monitored
The timing of the
7