- ページ 2

ロックス Gainsborough Austral Lock Virtus Four Point Hinged Door Mortice LockのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Gainsborough Austral Lock Virtus Four Point Hinged Door Mortice Lock 4 ページ。

Step 1: Door Preparation (cont.)
1.2
For Face Mount, route the door as per technical dimensions below
FACE MOUNT INSTALLATION
FRONT VIEW
OF STILE
21.0
R2.5 x 4
3.2
2 HOLES
Step 2: Installing the Lock
2.1
Insert lock into the stile
2.2
Secure with screws (max length 12mm)
Use fixing tabs for flush mount installation
30mm BACKSET
30mm BS
routing is 27.5mm
TOP VIEW OF STILE
from face
SIDE VIEW OF STILE
9 x 2 HOLES
20
8
10
R10
40mm BACKSET
40mm BS
routing is 37.5mm
from face
60mm BACKSET
60mm BS
routing is 57.5mm
from face
Fixing tab
Fixing tab